SENSATA | KLIXON 7235 / 7236 Series Overload Sensor
7.4 – 400 Amps, for AC, DC, single-phase or three-phase applications, SENSATA | KLIXON 7235 / 7236 Series Overload Sensor
Manufacturer | SENSATA / KLIXON |
---|---|
Product Category | AIRCRAFT CIRCUIT BREAKERS (Non-Temperature Compensated) |
Model | 7235 / 7236 Series |
Current Rating | 7.4 – 400 Amps |
Stock | Limited |
Documents & Downloads
SENSATA | KLIXON 7235 / 7236 Series Overload Sensor
7.4 – 400 Amps, for AC, DC, single-phase or three-phase applications, SENSATA | KLIXON 7235 / 7236 Series Overload Sensor
Manufacturer | SENSATA / KLIXON |
---|---|
Product Category | AIRCRAFT CIRCUIT BREAKERS (Non-Temperature Compensated) |
Model | 7235 / 7236 Series |
Current Rating | 7.4 – 400 Amps |
Stock | Limited |
Documents & Downloads
Technical Information
Introduction
SENSATA | KLIXON 7235 / 7236 Series Overload Sensor controls are designed for the remote sensing of overloads in aircraft electrical systems or other applicable remote systems. They are for the protection of 28 VDC circuits or for 120 VAC single–phase or three–phase circuits operating at 60 to 1000 Hz. For three-phase AC circuit protection, a 28 VDC control circuit is required. One three-phase relay or three single–phase relays with their coils wired in series may be used in the control circuit. With either arrangement, all three phases will trip open simultaneously when an overload exists in any one phase. Klixon overload sensing controls consist of a bi-metal thermal actuating disc in series with the load terminals and an auxiliary single–phase, double–throw switch fitted to the main base forming a compact vibration–proof construction. The aircraft relay is wired in series with the sensing control through the S2 terminal of the auxiliary switch. When the control senses and overloads, the Klixon disc operates the auxiliary switch, breaking circuit S1-S2 and making circuit S1-S3. This opens the relay, thus opening the load circuit.
Features
- Current rating 7.4-400 amps
- High reliability: does not switch overload current
- Adaptable for AC, DC, single-phase or three-phase applications
- Stops nuisance trips: thermal element unaffected by transient current surges
- It can be mounted in a remote location
- Uses minimum space: small circuit breaker for the size of the electrical load
- Only faulted line circuits opened: coordination ratings ensure that branch of circuit breakers trip first under fault conditions
- Typical use: remote sensing systems
Useful Links
-
Find more about SENSATA | KLIXON 7235 / 7236 Series Overload Sensor
-
Find more about Aircraft Circuit Breakers (Non-Temperature Compensated)